B&B Electronics Command Response Protocol HVD100A3 Manuale Utente Pagina 31

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 31
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 30
HDV100A3 Command & Response Manual 27 Cover Page
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Error Codes
Error Code Format:
Byte Number
Byte Value
Function
1
01
Start of frame
2
03
Number of control bytes
3
05
Function code error = 05
4
XY
ID of message that caused error
5
0Z
Error code (see chart below)
6
00
Number of data bytes
7
CS
Checksum
Error Code
Type of Error
Generated
Meaning of Error Generated
DEC
HEX
1
1
Gen
Inbuffer overflow; more than 127 bytes
2
2
Gen
Checksum mismatch
3
3
Gen
Protocol error; function, ID, code bad
4
4
J1708
J1708 input buffer full missed bus message
5
5
J1708
J1708 command unknown
6
6
J1708
J1708 output buffer full
7
7
8
8
J1939
Bus off
9
9
10
A
J1708
J1708 inbuffer overflow more than 127 bytes
11
B
12
C
13
D
14
E
15
F
Vedere la pagina 30
1 2 ... 26 27 28 29 30 31

Commenti su questo manuale

Nessun commento