12 HDV100A3 Command & Response Manual
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
J1708 Commands
Receiving Data from the J1708 Bus
After the HDV100A3 is set into its Intelligent mode of operation
and the RS-232 data rate is configured, you are now ready to communicate
with the J1708 bus. A receive command must be sent to the HDV100A3
before attempting to transmit to the bus. The receive message synchronizes
the HDV100A3 with the bus. To start receiving J1708 bus data, send the
following to the HDV100A3.
The number of control bytes
Function code 11 hex start receive
Number of data bytes (00 place holder)
Checksum (bytes 1 through 5 added together)
After sending this command to the device, the device will respond
with a confirmation message. The message confirms that the command was
received by the HDV100A3 and the checksum verified correctly. The reply
from the device is formatted as follows:
ID byte (ID of the sent message)
The confirmation message is sent in response to a command sent to the
device. The ID byte and the check-sum will change with different commands
but the format will remain the same. If the checksum is not correct an error
message is sent. Its format is covered at the end of this document.