24 HDV100A3 Command & Response Manual
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
The mask can be used to look at a group of messages:
To set the mask to filter on the J1939 priority field, the mask would be
loaded with:
(01, 06, 02, 04, E0, 00, 00, 00, 00, ED)
To set the mask to filter on the J1939 PGN field, the mask would be loaded
with:
(01, 06, 02, 04, 07, FF, F8, 00, 00, 0B)
To set mask to filter on both the priority field and the PGN field the mask
would be loaded with:
(01, 06, 02, 04, B7, FF, F8, 00, 00, BB)
Set Filter 1 to 4
Function codes 18 and 19, 28 and 29, 38 and 39, 48 and 49 are filter pairs.
These filters are set by sending the desired arbitration code to each filter, 1 to
4. The filters work with the mask function. If the mask is set to zero in a
position (don’t care) the value of the filter in that position doesn’t matter.
The filter arbitration field is set to match the aberration code of the incoming
message. A match of the filter “and” the mask will pass the message to the
PC. The X9 sets the filter On; X8 sets the filter Off, where X=1 through 4.
Important: the receiver and each filter must have a different arbitration
code. If the receiver and a filter are given the same arbitration code the
controller may become erratic. It will need to be powered-off reset to recover
from this error.
Function byte (18 or 19) (28 or 29) (38 or 39) (48 or 49)
MSB of arbitration field (J1939 priority bits)
LSB of arbitration field (J1939 source address)
To use the HDV100A3, the filter for a particular J1939 PGN the following
procedure must be followed.