B&B Electronics Command Response Protocol HVD100A3 Manuale Utente Pagina 29

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 31
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 28
HDV100A3 Command & Response Manual 25 Cover Page
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
1. Turn off the “Receive” function by sending (01, 02, 02, 00, 00, 05).
2. Set the “Mask” to the desired pattern (01, 06, 02, 04, XX, XX, XX, XX,
00, CS).
3. Set a filter (1 to 4) to the match value (01, 06, 02, YY, XX, XX, XX, XX,
00, CS). Be sure that this is NOT the same as any other filter value or the
HDV100A3 may become erratic.
4. Sending this value to the HDV100A3 will continuously send this match to
the PC.
Note that sending the “ Start Receive” or the “Stop Receive” command resets
the mask rendering the filters useless.