38 Chapter 5 Documentation Number UD128A8D4602 Manual
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph 353-91-792444 – Fax 353-91-792445
(2) BBDaqDevice
A BBDaqDevice is a single UD device in the collection of devices.
(3) BBIOPointGroups
Each Device has groups of BBIOPoints.
A BBIOPointGroup is a set of I/O points that share a common set of traits or
configuration options
.
(4) BBIOPoints
An I/O point is a single input or output representing a real-world
signal.
Enabling the Library for Use
In order to use the Library, you must enable it in your program.
Install the UD128A8D software using Setup.
Start VB6.0
Create a new project
The library is installed in
C:\Program Files\B&B Electronics\Data
Acquisition\UD128A8D\Components .
Select “References” from the “Project” menu item.