14 Chapter 2 Documentation Number UD128A8D4602 Manual
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph 353-91-792444 – Fax 353-91-792445
Operational Check - Connections
A Digital voltmeter or DC coupled oscilloscope is recommended for
checking signal levels and noise
.
Use a Terminal Blocks to DB25 connector for preliminary connections or
make your connections using the terminals on your prototype interface
board (prototyping board not included).
Steps - Refer to the I/O Pinouts (facing page)
1. Connect D/A output channels 0-3 to 4 of the A/D input channels
(Connections can verify D/A outputs and A/D inputs)
2. Connect a variable voltage source to the remaining A/D channels.
(as below) or connect to ground or +5V.
Analog
Input
UD128A8DExternal Circuit
Analog
GND
+
-
100 K
POT
5VDC
Fig. 2.1 - Analog Input using potentiometer for sensing position
3. Connect each digital output to a 2.2K to 3.2K resistor and LED.
Digital
Output
DIG
GND
UD128A8DExternal Circuit
2.2K
LED
Fig. 2.2 - Digital Output Active High LED On
3. After starting the BB-Dac Application and defining outputs, test the
digital inputs:
Connect each digital input to a 2.2K ohm resistor and then to ground or D-
REF+5 (see Figure 2.3 or 2.4).
When done, disconnect test connections and connect your devices.
Common Connections – Example Figures are shown later in this chapter as
a guide for commonly used inputs and outputs.