B&B Electronics Asynchronous to Synchronous Converter 2010 Manuale Utente Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 7
6 2010AS3297 Manual
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 434-7094
4.0 INSTALLATION
The Model 2010 is designed to be used in
pairs
, with one unit installed
between an asynchronous DTE and a synchronous DCE on either end of a
synchronous communication link. Figure 4 (below) illustrates a typical
Model 2010 installation.
Figure 4. Typical Model 2010 application
4.1 CONNECTING THE ASYNCHRONOUS PORT
The asynchronous port of the Model 2010 is a DB-25 female and is
configured as "DCE". Therefore, it wants to talk to a DTE device such as a
terminal or PC. The Model 2010 may be plugged directly into the DB-25
serial port of a DTE or connected via "straight through" cable.
4.2 CONNECTING THE SYNCHRONOUS PORT
The synchronous port of the Model 2010 is a DB-25 male and is
configured as "DTE." Therefore, it wants to talk to a DCE device such as a
modem or multiplexer. The Model 2010 may be plugged directly into the
DB-25 serial port of a DCE or connected via "straight through" cable.
Vedere la pagina 7
1 2 3 4 5 6 7 8 9 10 11 12

Commenti su questo manuale

Nessun commento