4. Properties Vlinx MESR9xx Modbus Gateway
Page 30 Manual Documentation Number MESR9xx-0109m
www.bb-elec.com/
www.bb-europe.com/
Modbus Gateway Name
Modbus Gateway Name is a unique name assigned to the Modbus gateway. It must be a
valid hostname as defined by RFC-952 and RFC-1123. The rules are:
It must consist only of the characters "A" to "Z", "a" to "z", "0" to "9" or "-"
It can start or end with a letter or a number, but it must not start or end with a "-".
It must not consist of all numeric values.
Gateway Serial Port Number
The Gateway Serial Port Number of the currently selected port is shown in this field.
MESR901-x Modbus Gateways feature one serial port.
MESR902D-x and MESR902T-x Modbus Gateways feature two serial ports.
Subnet Mask
The Subnet Mask specifies the network mask the Modbus gateway uses when on a
subnetted network.
For a Class A network (IP addresses 0.0.0.0 through 127.255.255.255) the default
subnet mask is 255.0.0.0.
For a Class B network (IP addresses 128.0.0.0 through 191.255.255.255) the
default subnet mask is 255.255.0.0
For a Class C network (IP addresses 192.0.0.0 through 233.255.255.255) the
default subnet mask is 255.255.255.0
For a Class D network (IP addresses 224.0.0.0 through 239.255.255.255) and
Class E Networks (IP addresses 240.0.0.0 through 255.255.255.255) the subnet
mask is ignored.
MESR9xxModbus Gateways come from the factory with a default subnet mask
value of: 255.255.255.0
Vedere la pagina 33